Variation |
---|
Technical Information
Electrical Data | EcoAir 410 | |
---|---|---|
Voltage | 1 x 230V1) | |
Rated Current2) A | 18.8 | |
Max. starting current A | 23.5 | |
Max. system impedance Ohm | 0.408 | |
IP Class | IP24 | |
ErP data for heat pump3) | ||
Energy class heating 35/55˚C (in package with control) |
A+++/A+ | |
Energy class heating 35/55˚C (without control) |
A++/A+ | |
Nominal heat output (Pdesignh) 35/55˚C kW |
10/9 | |
Operational data for heat pump | ||
Input power4) kW | 2.5 / 2.4 / 2.3 | |
Output power4) kW | 11.6 / 8.9 / 7.1 | |
COP4) | 4.86 / 3.65 / 3.03 | |
Heat pump dimensions | ||
Water volume l | 2.8 | |
Refrigerant quantity (R407C) kg | 2.7 | |
High pressure switch rating bar | 31 | |
Max. operating pressure water bar | 2.5 | |
Dimensions (H x W x D) mm | 1080 x 1245 x 545 | |
Compressor/oil type | Scroll / PVE FV50S | |
Air volume (low/high speed) m3/h | 4100 | |
Fan speed rpm | 493 | |
Fan input power w | 60 | |
Weight kg | 180 | |
Sound power dB(A) | 58 | |
Noise data 10m dB(A) | 33 |