Variation |
---|
Technical Information
EcoAir 610M | EcoAir 614M | EcoAir 622M | ||
---|---|---|---|---|
CTC no. | 588402001 | 588400001 | 588401001 | |
Weight (packaged weight) kg | kg | 174 (204) | 174 (204) | 192 (226) |
Dimensions (D x W x H) mm | mm | 545 x 1245 x 1080 | 545 x 1245 x 1080 | 645 x 1375 x 1180 |
Electrical data, connection | 400V 3N- 50Hz | |||
Rated current / with speed control in control unit A | A | 7.1 / 6.6 | 10.2 / 9.4 | 16.9 / 15.5 |
Recommended use fuse / with rps control in control unit A | A | 10/10 | 13/12 | 20 / 16 |
Energy efficiency class – heating system @ 35 / 55 ˚C 1) | A+++ | A+++ | A+++ | |
Energy efficiency class @ 35 / 55 ˚C | A++ | A+++ | A+++ | |
Supplied output @ W35 ˚C & A +7 @ min. rps / A -7 @ max. rps (EN14511) | 0.54 / 2.20 | 0.54 / 3.94 | 0.94 / 6.03 | |
Stated output @ W35 ˚C & A +7 @ min. rps / A -7 @ max. rps (EN14511) | kW | 2.55 / 6.20 | 2.55 / 8.69 | 4.75 / 13.99 |
Output range min. – max. kW | kW | 2.5 – 10 | 2.5 – 14 | 4.5 – 22 |
Ingress proyection (IP) | IP X4 | IP X4 | IP X4 | |
Nominal heating output (Pdesignh) kW @ moderate climate 35 / 55 ˚C | kW | 6/7 | 8/8 | 9/9 |
Nominal heating output (Pdesignh) kW @ cold climate 35 / 55 ˚C | kW | 7/7 | 11/11 | 13/12 |
COP @ W35 ˚C & A +7 @ min. rps / A -7 @ max. rps (EN14511) | 4.71 / 2.82 | 4.71 / 2.21 | 5.07 / 2.32 | |
SCOP moderate climate 35 / 55 ˚C (EN14511) | 4.8 / 3.6 | 4.9 / 3.8 | 4.9 / 3.8 | |
SCOP cold climate 35 / 55 ˚C (EN14511) | 3.8 / 3.2 | 3.9 / 3.1 | 4.3 / 3.5 | |
Refrigerant quantity (R407C, GWP 1774) kg | kg | 2.2 | 2.2 | 2.7 |
CO2- equivalent tonnes | tonnes | 3.903 | 3.903 | 4.79 |
Airflow, max. m3/h | m3/h | 3129 | 3129 | 5457 |
Sound power LWA (@ A7 & W35 / 55 dB(A) according to EN12102 appendix A.4) 2) | dB(A) | 53 / 53 | 51 / 52 | 55 / 55 |
Sound pressure LpA 5 m (A7 @ & W35 / 55) 2) dB(A) | dB(A) | 34 / 34 | 32 / 33 | 36 / 36 |
Sound pressure LpA 10 m (A7 @ & W35 / 55) 2) dB(A) | dB(A) | 28 / 28 | 26 / 27 | 30 / 30 |