CTC – EcoPart 616M – 400v GSHP – 588600002

EcoPart 616M 16kw Ground Source Heat Pump R407c – Three Phase – Inverter Driven

SKU: 7333077091743 Category:
Variation

Technical Information

3×400 V EcoPart 612M EcoPart 616M
CTC no. 588600001 588600002
Weight (packaged weight) kg 170 (188) 172 (190)
Dimensions (H x W x D) mm 775 x 596 x 673
Electrical Data, connection 400V 3N~ 50Hz
Energy efficiency class in heating system (with CTC EcoLogic) @ 35/55°C (A+++ à G) A+++/A+++
Energy efficiency class heat pump @ 35/55°C (A+++ à D) A+++/A+++
Rated current (recommended fuse 13 A) A 11.9 11.7
Output range (specified output cooling module) kW 2.5 – 11.8 4 – 16
Enclosure class (IP) IP X1
Specified output @ 5/35 | 5/45 | 5/55 @ 50 rps
(EN14511) kW kW 7.1 / 6.65 / 6.36 12.26 / 11.22 / 10.55
COP @ 5/35 | 5/45 | 5/55 @ 50 rps (EN14511) kW 5.62 / 4.26 / 3.57 5.07 / 3.87 / 3.14
Input power @ 0/35 | 0/45 | 0/55 @ 50 rps (EN14511) kW 1.27 / 1.54 / 1.78 2.34 / 2.80 / 3.27
Specified output @ 0/35 | 0/45 | 0/55 @ 50 rps (EN14511) kW 6.08 / 5.68 / 5.24 10.52 / 9.58 / 8.90
COP @ 0/35 | 0/45 | 0/55 @ 50 rps (EN14511) 4.78 / 3.68 / 2.95 4.50 / 3.43 / 2.72
SCOP (Pdesignh) @ cold climate 35/55°C (EN14825) 5.4 / 4.1 5.2 / 4.0
SCOP (Pdesignh) @ moderate climate 35/55°C (EN14825) 5.5 / 4.3 5.5 / 4.2
Refrigerant quantity (R407C, fluorinated greenhouse gas GWP 1774) kg 2.4 2.2
CO2 equivalent tonnes 4.258 3.903
Sound power LWA @ 0/35 | 0/55 (EN 12102) dB(A) 39 / 41 36 / 40