GSI 612 12kw Ground Source Heat Pump R407c – Three Phase – Inverter Driven – Built in Control

SKU: 7333077094270 Category:
Variation

Technical Information

Single phase (230V) GSi 612
CTC no. 587305001
Weight (packaged weight) kg 252 (282)
Dimensions (H x W x D) mm 1910 x 596 x 673
Required ceiling height mm 1940
Electrical Data, connection 230V 1N~ 50Hz
Energy efficiency class in heating system @ 35/55°C (A+++ to G) A+++ / A+++
Energy efficiency class heat pump @ 35/55°C (A+++ to D) A++ / A++
Energy efficiency class DHW / charge profile (EN16147) (A+ to F) A / XL
DHW-performance (V40) Volume 40°C @ Economy/Normal/Comfort (EN16147) litres 215 / 235 / 311
Rated current (recommended fuse 50 A) A 49
Max. electric heater output @ group fuse 25/32/35/50/63 A kW – / 0.9 / 2.3 / 5.5 / 5.5
Output range (specified output cooling module) kW 1.6 – 12.5
Output range immersion heater kW 0.3 – 5.5
Ingress protection class (IP) IP X1
Specified output @ 5/35 | 5/45 | 5/55 @ 50 rps (EN14511) kW 6.62 / 6.27 / 6.09
COP @ 5/35 | 5/45 | 5/55 @ 50 rps (EN14511) 5.22 / 3.95 / 3.20
Specified output @ 0/35 | 0/45 | 0/55 @ 50 rps (EN14511) kW 5.75 / 5.46 / 5.22
COP @ 0/35 | 0/45 | 0/55 @ 50 rps (EN14511) 4.49 / 3.49 / 2.79
SCOP (Pdesignh) cold climate @ 0/35 | 0/55 (EN14825) 5.3 / 4.0
SCOP (Pdesignh) moderate climate @ 0/35 | 0/55 (EN14825) 5.1 / 3.9
Water volume – Heating system (V) litres 229
Water volume – Water supply system (V) litres 1.7
Refrigerant quantity (R410A, fluorinated greenhouse gas GWP 2088) kg 2.3
CO2 equivalent tonnes 4.802
Sound power @ 0/35 | 0/55 (according to EN12102) dB(A) 38 / 43